11 Kalite Patojèn Respiratwa
Non pwodwi
HWTS-RT162A 11 Kalite Twous Deteksyon Asid Nikleyik Patojèn Respiratwa(PCR fliyoresans)
Chanèl
靶标 | Chanèl | |||
核酸反应液A | 核酸反应液B | 核酸反应液C | 核酸反应液D | |
HI | Smet | MP | Janm | FAM |
SP | PA | Bp | / | CY5 |
KPN | ABA | Bpp | Koupon | ROX |
内参 | 内参 | 内参 | 内参 | VIC/HEX |
Epidemyoloji
Enfeksyon nan aparèy respiratwa yo se yon klas maladi enpòtan ki poze yon menas grav pou sante moun, epi etid yo montre ke pifò enfeksyon nan aparèy respiratwa yo koze pa patojèn bakteri ak/oswa viral ki ko-enfekte lame a, sa ki lakòz yon ogmantasyon nan gravite maladi a e menm lanmò, kidonk klarifye patojèn nan pèmèt yon tretman siblé epi amelyore to siviv pasyan an.[1,2].
Paramèt teknik
Depo | ≤-18℃ |
Dire lavi etajè | 12 mwa |
Kalite echantiyon | Krache |
Ct | HI、SP、KPN、PA、ABA、Smet:Ct≤33BP, Bpp, MP, Cpn, Janm: Ct≤38 |
CV | <5.0% |
LoD | Klebsiella pneumoniae, Streptococcus pneumoniae, Haemophilus influenzae, Pseudomonasaeruginosa, Acinetobacter baumannii, Stenotrophomonas maltophilia ak Legionellapneumofila: 1000 CFU/mL; Bordetella pertussis ak Bacillus parapertussis: 500 CFU/mL; Mycoplasma pneumoniae ak Chlamydia pneumoniae: 200 kopi/mL. |
Espesifikite | Rezilta tès kwa-reyaktivite yo te montre ke pa te gen okenn kwa-reyaktivite ant twous sa a ak Cytomegalovirus, viris Herpes simplex tip 1, viris Varicella-zoster, viris Epstein-Barr, Bordetella pertussis, Corynebacterium, Escherichia coli, Haemophilus influenzae, Lactobacillus, Legionella pneumophila, Moraxella catarrhalis, souch atenye Mycobacterium tuberculosis, Neisseria meningitidis, Neisseria, Pseudomonas aeruginosa, Staphylococcus aureus, Staphylococcus epidermidis, Streptococcus pyogenes, Streptococcus salivarius, Acinetobacter baumannii, Stenotrophomonas maltophilia, Burkholderia cepacia, Corynebacterium striatum, Nocardia, Serratia marcescens, Citrobacter, Cryptococcus, Aspergillus fumigatus, Aspergillus flavus, Pneumocystis jiroveci, Candida. albicans, Rothia mucilaginosus, Streptococcus oralis, Klebsiella pneumoniae, Chlamydia psittaci, Coxiella burnetii ak asid nikleyik jenomik imen. |
Enstriman Aplikab yo | Sistèm PCR an tan reyèl Applied Biosystems 7500 yo Sistèm PCR rapid an tan reyèl Applied Biosystems 7500 QuantStudio®5 Sistèm PCR an tan reyèl Sistèm PCR an tan reyèl SLAN-96P Siklis Limyè®480 Sistèm PCR an tan reyèl Sistèm Deteksyon PCR an Tan Reyèl LineGene 9600 Plus MA-6000 Siklis tèmik kantitatif an tan reyèl Sistèm PCR an tan reyèl BioRad CFX96 la Sistèm PCR an tan reyèl BioRad CFX Opus 96 |
Koule Travay
Twous Jeneral ADN/ARN Macro & Micro-Test (HWTS-3019) (ki ka itilize avèk Ekstraktè Asid Nikleyik Otomatik Macro & Micro-Test (HWTS-3006C, HWTS-3006B)) pa Jiangsu Macro & Micro-Test Med-Tech Co., Ltd. Ajoute 200µL nanfizyolojiksolisyon saline nan presipite trete a, epi etap ki vin apre yo ta dwe fèt dapre enstriksyon yo. Volim elisyon rekòmande a se 100 µL.